©2007, X-Rite, Inc.
Examolite
®
and Prooflite
®
Overhead Luminaire
OPERATION MANUAL
Part No. 17500030
INTRODUCTION. The following products are described in this manual:
Examolite TC-440B is an overhead luminaire that provides blended
fluorescent daylight at 7500K. It is used for grading, sorting, and visual
quality inspections.
Examolite SD-840B is an overhead luminaire that provides simulated
fluorescent Daylight (D75, D65, or D50), llluminant A (Incandescent), and
cool white fluorescent (CWF). It is used for visual color evaluations,
metamerism testing, and in applications where products need to be
evaluated under multiple light sources.
Prooflite PLD-440 is an overhead luminaire that provides simulated
fluorescent daylight (D75, D65, or D50). It is a 4-lamp, single source fixture
typically used in viewing booth installations for visual color evaluations.
Prooflite PLD-840 is an overhead luminaire that provides simulated
fluorescent daylight (D75, D65, or D50). It is an 8 lamp, single source
fixture that provides higher levels of illumination for open room
applications. A dual source fixture can also be achieved by combining four
lamps of two different sources in one PLD-840 fixture. It is used for visual
color evaluations.
SAFETY INSTRUCTIONS
PLEASE READ AND FOLLOW INSTRUCTIONS—Follow all instructions before attempting installation and operation.
KEEP INSTRUCTIONS—Retain these instructions for future reference. Once you have read these instructions, keep
them available for other operators to read.
OBEY ALL WARNINGS—Please comply with all warnings and safeguards in these instructions. They have been written
to keep you and your fixture safe.
CHOOSE PROPER POWER SOURCES—Use the proper power source. If you have any doubt, consult the label on the
inside of the fixture for this information.
NOT EXPLOSION-PROOF—This fixture is not explosion-proof and should not be used in a hazardous atmosphere with
exposure to flammable substances.
TURN OFF FIXTURE BEFORE CHANGING ANY LAMPS—Always turn off the fixture before you change lamps.
Always turn off power before cleaning surfaces.
ALLOW LAMPS TO COOL BEFORE TOUCHING THEM—Do not touch the hot lamps; allow them to cool.
CLEAN PROPERLY—You can wipe the lamps and reflector with a clean, white lint-free cloth. Clean the diffuser and
housing with a dampened cloth containing a mild soap.
DO NOT OPERATE DURING LIGHTNING STORMS—As an added protection during a lightning storm, turn off the
fixture so that it will not experience electrical power surges or unnecessary power drops that could result in damage to
lamps and electrical circuitry.
SERVICE PROPERLY—With the exception of lamp replacement, do not attempt to service this product yourself. If you
should attempt unauthorized repairs, you may invalidate the warranty that is active on your fixture. For any other
malfunctions in operation, contact X-Rite Technical Service.
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9 10

Shrnutí obsahu

Strany 1 - Overhead Luminaire

©2007, X-Rite, Inc. Examolite® and Prooflite® Overhead Luminaire OPERATION MANUAL Part No. 17500030 INTRODUCTION. The following products are described

Strany 2 - Input Power Requirements

Corporate Headquarters - USA 4300 44th Street SE Grand Rapids, Michigan 49512 Phone 1 800 248 9748 or 1 616 803 2100

Strany 3 - Installation Procedure

Page 2 GENERAL INFORMATION Major Components Your overhead luminaire is specifically designed to meet the needs of visual color evaluation. The housing

Strany 4 - Fixture Net Weights

Page 3 Recommendations For Surround X-Rite fixtures are designed for color inspection and therefore it is important that precautions be taken to ensur

Strany 5 - WIRING THE FIXTURE

Page 4 CHAIN HUNG MOUNTING PROCEDURE Recommendations For Location Of Fixtures There are many applications for X-Rite overhead luminaires and therefore

Strany 6 - Lamp Replacement Schedule

Page 5 WIRING THE FIXTURE CAUTION Wiring should only be performed by a professional electrician. General Connection of the individual ballast input le

Strany 7 - SPECIFICATIONS

Page 6 MAINTENANCE Cleaning An accumulation of dust, dirt, etc. will decrease the intensity of the light and also change the quality of the illuminati

Strany 8 - WARRANTY INFORMATION

Page 7 SPECIFICATIONS The following is a list of useful specifications. Examolite Model TC-440B SD-840B Light Sources Blended Daylight, 7500K (D7

Strany 9

Page 8 SPARE PARTS Examolite TC-440B (Daylight) 48 "Lamp Kit A-LK/ETC4448 This kit consists of eight (8), F40T12/EX, 8800K, fluorescent daylight

Strany 10